• 10-0070
    Disconnect Handle for Allen Bradley Disconnects
  • 10-0071
    Disconnect Extension Shaft for Allen Bradley Disconnects
  • 10-0981
    Allen Bradley Disconnect for ETL 480V 14-18 Bender
    10-0983
    Allen Bradley Disconnect for ETL 240V 14-18 Bender

    10-0966
    Aux Contact for ETL Disconnects
  • 11-427
    End Anchor (2 required to mount Allen Bradley Disconnect)

    11-437
    Din Rail
    (6in required to mount Allen Bradley Disconnect)
    (8in required to mount Mersen Disconnect)
  • 10-1015A
    Mersen Disconnect Handle
    10-1019A
    Mersen Disconnect Shaft

    #11 ETL RMS Bender
  • 10-1020
    Mersen Fused Disconnect

    #11 ETL RMS Bender
  • 10-0964
    250VA Dual Voltage ETL Transformer
    wired complete with fuses

    All Benders
  • 10-0219
    480V Variable Frequency Drive

    10-0217
    240V Variable Frequency Drive

    RMS 11 Bender only
  • 10-0953
    3 1/2A 240V Primary Fuse
    10-0954
    1 1/2A 480V Primary Fuse
    10-0955
    1 4/10A 600V Primary Fuse

    For Primary on 250VA Control Transformer
    All Benders with fusable primary
  • 10-0184
    2 1/2A Fuse
    For Secondary on 250VA Control Transformer
  • 10-0184
    ` 2 1/2A Fuse
    ` For Secondary on 250VA Control Transformer
    `
    ` All Benders
  • 10-1070
    12V Power Supply (Din Rail Mount)

    #11 ETL RMS Bender
  • 10-1001
    Mini SQ Relay

    10-1003
    Mini SQ Relay Base

    10-1005
    Mini SQ Retainer Clip
  • 10-1072
    12V Relay

    10-1071
    12V Relay Base

    #11 ETL RMS Bender
  • 62-130
    Inverter Interface Board for RMS #11 Bender
  • 10-0147
    Line Contactor for all RMS Benders
  • 10-0155
    505 Size 1 Reversing Starter set
    Reversing Starter for #14 Bender with 480V RMS Electrical Panel
    Reversing Starter for #18 Bender with 480V RMS Electrical Panel
  • 10-0157
    505 Size 2 Reversing Starter set
    Reversing Starter for #14 Bender with 240V RMS Electrical Panel
    Reversing Starter for #18 Bender with 240V RMS Electrical Panel
  • 10-0179
    Heater for 505 Starters
    Must Specify #11, #14, or #18 Bender 240V or 480V
  • 10-0174
    Heater Block for 505 Starters
  • 10-0171
    Auxillary Contact for 505 Starters
  • 10-0178
    Contact (Single Pole Kit) for 505 Starters
    *NOTE - 6 REQUIRED TO REBUILD REVERSING STARTER
  • 10-0177
    Interlock for 505 Starters
  • 10-0165
    Size 0 Reversing Starter set
    Reversing Starter for #14 Bender with 480V ETL Electrical Panel
    Reversing Starter for #18 Bender with 480V ETL Electrical Panel
  • 10-0145
    Starter for #14 Bender with 240V ETL Electrical Panel
    Starter for #18 Bender with 240V ETL Electrical Panel
    *NOTE - QUANTITY 2 REQURED IN MACHINE

    10-0167
    Reverse Lockout
    *NOTE - QUANTITY 1 REQUIRED PER 2 STARTERS
  • 10-0237
    Allen Bradley Limit Switch
    Replaces Omron
    Old Style RMS Benders
    Mounting Hole Spacing 2 5/8"
  • 10-0235
    Honeywell Micro Type Limit Switch
    Some Arnold / DMI Benders
  • 10-0239
    Allen Bradley Limit Switch
    Some Arnold / DMI Benders
  • 10-0241
    Arm for Allen Bradley Limit Switch
    Arnold / DMI Benders
  • 10-0234
    Proximity Sensor
    New Style Benders with Proximity Style Neutral
  • 10-0251
    Green Start Button
    10-0279
    Start Tag
  • 10-0253
    Bender On/Off Switch
    10-1065
    On/Off Tag
  • 10-0273
    Neutral Selector Switch
    10-0274
    Neutral Contact
    10-0250
    1-2-3 Tag
  • 65-020
    Manual Override Switch
    10-1066
    Manual Override Tag
  • 10-0259
    E-Stop Switch
    10-0281
    E-Stop Tag
  • 10-0258
    E-Stop Red Button Only
  • 11-328A
    30mm Hole Plug for Electrical Boxes
  • 11-301
    2-Hole Box
  • 11-328
    4-Hole Box
  • 62-260
    3 Position Switch - Wired
  • 18-B1000
    Foot Pedal Wired with Cord
    NOTE - PLEASE SPECIFY 10' OR 20' LONG CORD
  • 62-160
    Bender Control Cable
  • 62-180
    Bender Encoder Cable
  • 62-450
    Suppressor 130V
    62-455
    Suppressor 480V
  • 10-0835
    Sumitomo 25FW Rectifier
    #11 RMS Bender
    #14 RMS Bender
    #18 RMS Bender
  • 18-B095
    Laser Scanner System

    Includes all components required to wire up laser scanner system into existing bender.

    Note: Bender must have manual override capability to install this system.
  • 18-B098
    Proximity Conversion
    Customer Must specify for #11, #14, or #18 Bender
  • 18-B099
    Emergency Flapper with Clamp
  • 10-0233
    Limit Switch with Cable
  • 18-B110
    Emergency Flapper Switch with Magnetic Base
  • 09-123
    Switch Bracket for Magnetic Base

    03-032
    Flat Head Bolt for Magnetic Base
  • 18-B109
    Emergency Flapper Switch with Bracket for Backup Ram
  • 18-B109A
    Switch Bracket for Backup Ram
  • 60-070
    Dual 5/12V Power Supply for Bender Controller
  • 60-060
    3.3V Power Supply (Color models only)
  • 60-061
    5V Power Supply (Color models only)
  • 60-062
    12V Power Supply (Color models only)
  • 65-030
    Keypad for New Style Bender Controllers
  • 62-478
    Directional Light Kit Modification for Bender Controllers
  • 62-479
    Directional Light Kit
  • 62-270
    Barcode Scanner for Bender Machine Controller
  • 62-271
    Barcode Scanner Serial Cable for BMC
THIS IS A SPACER